Home » Planning a Quieter Seresco Pool Dehumidifier Retrofit in Kingston

Planning a Quieter Seresco Pool Dehumidifier Retrofit in Kingston

2–3 minutes

If guests can hear the pool equipment from a bedroom, put that room on the retrofit drawings. For a Kingston hotel planning a Seresco indoor pool dehumidifier replacement, the most useful place to judge the result may be the pillow on the other side of the mechanical-room wall. Identify that location before the old unit comes out, while there is still a chance to document what people hear.

Record the sound where guests hear it

Ask staff to identify the room, the time and the character of the sound. A steady rush at a supply grille gives the designer a different starting point from a low hum that is strongest beside the bed. If the complaint occurs overnight, arrange access during a similarly quiet period. Note which equipment is running, including nearby pumps and fans, so the project team can investigate the source.

If quiet operation is part of the purchase decision, have the project designer specify the measurement location, operating conditions and acceptance criterion in the bid documents. A supplier’s sound figure for the cabinet alone cannot tell an owner how a finished guest room will sound.

Ask bidders to show the base and the duct connections

Seresco’s installation manual calls for a firm, level base with provision to absorb vibration. It also recommends flexible duct connections to reduce the transmission of sound and vibration. These details address different paths into the building. Have bidders show both on the proposed installation drawing and identify who supplies each item.

For example, a quote might include flexible duct connectors but assume the existing support frame can stay. Ask who will assess that frame for the replacement unit and what happens to the price if it needs modification. The designer can then resolve the assumption while there is still time to compare bids.

Put the guest-room check on the start-up schedule

Reserve access to the same room for the post-installation check. Ask the commissioning team to record the operating mode, other equipment running and the result at the agreed location. If a hum returns only when the compressor starts, note that transition for the installer. A check conducted with the fan alone would miss the condition the hotel wanted to resolve.

Planning a Seresco pool dehumidifier retrofit in Kingston? Call King Air at 905-939-0777 with the unit model, a floor plan and the location where staff or guests hear the equipment. Discuss your Seresco system with King Air.